參數(shù)型號輸入電源容量(KW)X射線管電壓(KV連續(xù)可調)X射線管X射線發(fā)生器穿透厚度(mm)控制器焦點尺寸(mm)輻射角重量(Kg)尺寸(長×寬×高)(mm)重量(Kg)尺寸(長×寬×高)(mm)XXQ-1005﹥1
參數(shù)
型號 | 輸入電源容量(KW) | X射線管 電壓(KV 連續(xù)可調) | X 射 線 管 | X 射 線 發(fā) 生 器 | 穿透 厚 度 (mm) | 控制器 | |||
焦點尺寸(mm) | 輻 射 角 | 重量(Kg) | 尺寸(長×寬×高) (mm) | 重量(Kg) | 尺寸(長×寬×高) (mm) | ||||
XXQ-1005 | ﹥1.2 | 50~100 | 0.8×0.8 | 40°+ 5° | 10 | 210×210×540 | 8 | 9.5 | 300×150×290 |
XXH-1005 | ﹥1.2 | 50~100 | 1.0×3.5 | 360°×25° 360°×30° | 10 | 210×210×540 | 5 | 9.5 | 300×150×290 |
XXQ-1605 | ﹥1.5 | 80~160 | 0.8×0.8 | 40°+ 5° | 17 | 224×224×580 | 18 | 9.5 | 300×150×290 |
XXH-1605 | ﹥1.5 | 80~160 | 1.0×3.5 | 360°×25° 360°×30° | 17 | 224×224×580 | 15 11 | 9.5 | 300×150×290 |
XXG-1605 | ﹥1.5 | 80~160 | 0.8×0.8 | 40°+ 5° | 17 | 224×224×570 | 18 | 9.5 | 300×150×290 |
XXQ-2005 | ﹥2.0 | 100~200 | 1.5×1.5 | 40°+ 5° | 20 | 280×280×650 | 29 | 9.5 | 300×150×290 |
XXH-2005 | ﹥2.0 | 100~200 | 1.0×3.5 | 360°×25° 360°×30° | 20 | 280×280×650 | 27 24 | 9.5 | 300×150×290 |
XXG-2005 | ﹥2.0 | 100~200 | 1.5×1.5 | 40°+ 5° | 23 | 224×224×570 | 29 | 9.5 | 300×150×290 |
XXQ-2505 | ﹥2.5 | 150~250 | 2.0×2.0 | 40°+ 5° | 37 | 320×320×720 | 39 | 9.5 | 300×150×290 |
XXH-2505 XXHZ-2505 | ﹥2.5 | 150~250 | 1.0×2.4 | 360°×25° 360°×30° | 37 | 320×320×730 | 37 34 | 9.5 | 300×150×290 |
XXG-2505 | ﹥2.5 | 150~250 | 2.0×2.0 | 40°+ 5° | 23 | 280×280×595 | 39 | 9.5 | 300×150×290 |
XXGZ-2505 | ﹥2.5 | 150~250 | 1.0×2.4 | 360°×30° | 31 | 295×295×700 | 34 | 9.5 | 300×150×290 |
XXQ-3005 | ﹥3.0 | 170~300 | 2.3×2.3 | 40°+ 5° | 42 | 320×320×820 | 50 | 9.5 | 300×150×290 |
XXH-3005 XXHZ-3005 | ﹥3.0 | 170~300 | 1.0×2.3 | 360°×25° 360°×30° | 42 | 320×320×820 | 47 40 | 9.5 | 300×150×290 |
XXG-3005 | ﹥3.0 | 170~300 | 2.3×2.3 | 40°+ 5° | 31 | 320×320×700 | 50 | 9.5 | 300×150×290 |
XXGH-3005 XXGZ-3005 | ﹥3.0 | 170~300 | 1.0×2.3 | 360°×25° 360°×30° | 31 | 320×320×645 | 47 44 | 9.5 | 300×150×290 |
XXQ-3205 | ﹥3.2 | 170~320 | 2.3×2.3 | 40°+ 5° | 45 | 320×320×730 | 55 | 9.5 | 300×150×290 |
XXH-3205 XXHZ-3205 | ﹥3.2 | 170~320 | 1.0×5.0 | 360°×25° 360°×30° | 45 | 320×320×820 | 52 45 | 9.5 | 300×150×290 |
XXQ-3505 | ﹥3.5 | 170~350 | 2.3×2.3 | 40°+ 5° | 50 | 320×320×800 | 60 | 9.5 | 300×150×290 |
XXH-3505 XXHZ-3505 | ﹥3.5 | 170~350 | 1.0×5.0 | 360°×25° 360°×30° | 35 | 320×320×820 | 55 50 | 9.5 | 300×150×290 |
XXG-3505 | ﹥3.5 | 180~350 | 2.3×2.3 | 40°+ 5° | 36 | 320×320×690 | 60 | 9.5 | 300×150×290 |
XXGZ-3505 | ﹥2.5 | 150~250 | 1.0×2.4 | 360°×30° | 31 | 295×295×700 | 34 | 9.5 | 300×150×290 |
XXG-3606 | ﹥3.6 | 160~360 | 2.3×2.3 | 40°+ 5° | 37 | 320×320×660 | 75 | 9.5 | 300×150×290 |
穿透厚度條件:1、焦 距 600 mm; 2、曝 光 時 間5min 3、天津型膠片,雙面鉛箔增感 4、暗室處理:溫度20℃ ±2℃ , 顯影時間5 min 5、黑 度 D ≥1.5 |
1、 型 號: GP-XXG-1605(陶瓷管)
2、 電源容量: >900 W
3、 管 電 壓: 30~160 KV連續(xù)可調,管電流:3 mA
4、 焦點尺寸: 2.0×2.0 mm
5、 輻射角度: 40°+5°
6、 穿透: 18 mm(A3鋼,焦距:600 mm,時間:5分鐘)
7、 發(fā)生器重量: 16 Kg
8、 控制器重量: 9.0Kg
9、 發(fā)生器體積: 230×230×650 mm
10、控制器體積: 296×145×285 mm
11、工作頻率: 40 KH
便攜式X射線探傷機LX-XXQ-1605X射線探傷機的穿透能力取決于X射線探傷機的容量,既X射線探傷機的管電壓,管電壓愈高,X射線愈硬,能量愈大,穿透能力就愈強,穿透能力與管電壓平方成正比。另外,在相同的管電壓下,還與被檢驗工件的材質的密度等性質有關,也就是與被檢驗工件對X射線的衰減能力有關。對于鋼鐵等重金屬以及較厚的工件,由于其對X射線的衰減能力較強,故應選擇管電壓較高的X射線探傷機;而對于鋁、鎂等輕金屬和較薄的工件,可以選擇管電壓較低的X射線探傷機。